Home > Pond Pumps >

  AquascapePRO™ 7500 Pump
  AquascapePRO 7500 Pump
 
Alternative Views:

List Price: $799.99
Our Price: $695.99
You save $104.00!


Availability:: Usually Ships in 24 Hours
Product Code: 20004

Description
 
2" Discharge, 1200 watts, Max. head height 42 ft., 6700 GPH at 5 ft., 20 ft. cord length.

AquascapePro™ horizontal pond pumps are energy efficient and low maintenance. Quiet and efficient, these oil-free pumps have stainless steel construction, along with rubber feet to reduce vibration. AquascapePro™ horizontal pond pumps are energy efficient and low maintenance. Quiet and efficient, these oil-free pumps have stainless steel construction, along with rubber feet to reduce vibration. With high head heights and huge flow rates, the AquascapePro™ line excels in the water gardening industry.

   * Pump Performance
     - GPH: 6700
     - Watts: 1200
     - Discharge: 2" Female
     - Operating Cost/Month: $83.90
     - Max Head: 42'
   * Includes: 20' cord
     Warranty: 2 yrs.
     Weight: 22 lbs.

-----------

Installation & Maintenance Instructions

Electrical Connections

Pumps must be used in a circuit protected by a ground fault interrupter.

All model pumps and control panels must be properly grounded per the national electrical code or canadian electric code, state, province and local codes. Improper grounding voids warranty. DO NOT USE THE POWER CABLE TO LIFT PUMP!

WARNING!

Products Returned Must Be Cleaned, Sanitized, Or Decontaminated As Necessary Prior To Shipment. To Insure That Employees Will Not Be Exposed To Health Hazards In Handling Said Material. All Applicable Laws And Regulations Shall Apply.

1) Getting to Know Your 7500 Pump

Flow Rate @ 5ft. Head                       6,700 gph
Watts                                               1200*
Volts                                                120
Shut-off Height                                  42 ft.
Discharge                                          2” female
Cable length                                      20 ft.
Max Amps                                        10
Horsepower                                       1/2

* Operating watts and electrical costs based on 5’ total dynamic head.

2) Installation Suggestions

• Do not wear loose clothing that may become entangled in the impeller or other moving parts.
• Only qualified personnel should install, operate and repair pump.
• Keep clear of suction and discharge openings. DO NOT insert fingers in pump with power connected.
• Do not block or restrict discharge hose, as discharge hose may whip under pressure.
• Make sure lifting handles are securely fastened each time before lifting.
• Do not exceed manufacturers recommendation for maximum performance, as this could cause the motor to overheat.
• Secure the pump in its operating position so it can not tip over, fall or slide.
• Submersible Pumps are not approved for use in swimming pools.
• Do not operate pump without safety devices in place. Always replace safety devices that have been removed during service or repair.
• Any wiring of pumps should be performed by a qualified electrician.
• Cable should be protected at all times to avoid punctures, cut, bruises and abrasions–inspect frequently.
• Never handle connected power cords with wet hands.
• Do not remove cord and strain relief. Do not connect conduit to pump.
• To reduce risk of electrical shock, all wiring and junction connections should be made per the NEC or CEC and applicable state or province and local codes. Requirements may vary depending on usage and location.
• Use only in fully assembled state.

IMPORTANT!
Aquascape, Inc. is not responsible for losses, injury, or death resulting from a failure to observe these safety precautions, misuse or abuse of pumps or equipment.

General Information

IMPORTANT!

Read all instructions in this manual before operating pump.

) Receiving

Upon receiving the pump, it should be inspected for damage or shortages. If damage has occurred, file a claim immediately with the company that delivered the pump. If the manual is removed from the packaging, do not lose or misplace.

4) Installation

Location:
These pumping units are self-contained and are recommended for use in an Aquascape skimmer or snorkel, sump, lift station or basin. This pump is designed to pump pond water and shall NOT be installed in locations classified as hazardous in accordance with the National Electrical Code (NEC), ANSI/NFPA 70 or the Canadian Electrical Code (CEC). Never install the pump in a trench, ditch or hole with a dirt bottom; the legs will sink into the dirt and the suction will become plugged.

Check Valve:
With the skimmer properly installed in ground, feed flex PVC discharge pipe leading to the BioFalls® through hole in back of skimmer. Slide collar piece over PVC FIRST, then glue pipe end cap to PVC tubing (see fig. 2 on page 5). The fitting on the bottom of the Aquascape check valve assembly should be threaded into the pump discharge. Standing behind the Skimmer set the pump along the right side, inside the skimmer vault3 on page 6). Connect the check valve assembly by sliding the collar up to the check valve and tightening.
*See installation instructions for other aspects of pump and pond maintenance.

Submergence:
It is recommended that the pump be operated in the submerged condition. The pump is equipped with a thermal protector which will shut down the pump temporarily in low water conditions. However, this is not recommended for extended periods of time.

Discharge:
An Aquascape check valve is recommended for each pump being used. The Aquascape check valve is used to prevent backflow into the sump. Excessive backflow can cause flooding and/or damage to the pump.

Caution:

If the pump is operated while the electrical cable is drooping, it may become caught in the impeller, causing the cable to be cut, damaging the impeller or causing seepage in the pump, which can result in electrical leakage or shock.

5) Troubleshooting

CAUTION! Always disconnect the pump form the electrical power source before handling. If the system fails to operate properly, carefully read instructions and perform maintenance recommendations. If operating problems persist, the following chart may be of assistance in identifying and correcting them. MATCH “CAUSE” NUMBER WITH CORRELATING “CORRECTION” NUMBER. NOTE: Not all problems and correction will apply to each pump model.

Problems & Causes (Correction)

• Pump will not run.
- Poor electrical connection, blown fuse, tripped breaker or other interruption of power; improper power supply. (1)
- Insufficient water level. (2)

• Pump hums but doesn’t run.
- Incorrect voltage (1)
- Impeller jammed or loose on shaft, worn or damaged, impeller cavity or inlet plugged. (7)

• Pump delivers insufficient capacity.
- Incorrect voltage (1)
- Excessive inflow or pump not properly sized for application. (3)
- Discharge restricted. (4)
- Check valve stuck closed or installed backwards. (5)
- Shut-off valve closed. (6)
- Impeller jammed or loose on shaft, worn or damaged, impeller cavity or inlet plugged. (7)
- Air may be trapped in pump impeller chamber (8)

• Pump cycles too frequently or runs periodically when fixtures are not in use.
- Check valve stuck closed or installed backwards. (5)
- Insufficient water level. (2)

• Pump Shuts off and turns on independent of switch. (trips thermal overload protector).
CAUTION! Pump may start unexpectedly. Disconnect power supply.

- Incorrect voltage (1)
- Excessive inflow or pump not properly sized for application. (3)
- Impeller jammed or loose on shaft, worn or damaged, impeller cavity or inlet plugged. (7)
- Excessive water temperature (internal protection only). (11)

• Pump operates noisily or vibrates excessively.
- Debris in impeller cavity or broken impeller. (7)
- Fittings on pump or check valve not secured properly (14)

6) Corrections

1. Check all electrical connections for security. Have electrician measure current in motor leads, if current is within ±20% of locked rotor Amps, impeller is probably locked. If current is 0, overload may be tripped. Remove power, allow pump to cool, then recheck current.
2. Make sure water level is at or close to proper height on skimmer face plate.
3. Recheck all sizing calculations to determine proper pump size.
4. Check discharge line for restrictions, including ice if line passes through or into cold areas.
5. Remove and examine check valve for proper installation and freedom of operation.
6. Open valve.
7. Check impeller for freedom of operation, security and condition. Clean impeller cavity and inlet of any obstruction.
8. Remove pump or tilt pump to allow trapped air to escape from impeller chamber.
9. Check rotation. If power supply is three phase, reverse any two of three power supply leads to insure proper impeller rotation.
10. Repair fixtures as required to eliminate leakage.
11. Check pump temperature limits & fluid temperature.
12. Replace portion of discharge pipe with flexible connector.
13. Check for leaks around basin inlet and outlets.
14. Check fittings and tighten if needed

Proper Water Level with respect to skimmer face: Water level should be about 3/4” to 1 1/2” below the top of the skimmer face opening

7) Care After Pump Operation

You don’t specifically have to care for this Aquascape pump, however, you are requested to observe the following points after using the pump:
• If freezing temperatures are predicted and the pump is not in operation, remove the pump from the water, wash with clean water and remove any debris or water in the impeller chamber. Store pump in a bucket of water in a non-freezing location. This will help prevent the seals from drying out on the pump.
• Our pumps are all 300 series s.s. or plastic components. No rust should be present.

Average Customer Review: Based on 2 reviewsWrite a review.

Related Products...
Snorkel Vault Extension
Our Price: $130.49
Add
Snorkel Vault Extension
Atlantic Water Gardens™ TidalWave SH-Series Pumps

Add
TidalWave SH-Series Pumps
Impeller 75 Statuary
Our Price: $4.78
Add
Impeller For 75 Gph Statuary Pump
AquaSurge 7000 Pump
Our Price: $1,009.19
Add
PRO-Fit Signature Series 8.0 with AquaSurge 7000 Pump
Atlantic Water Gardens™ TidalWave2 TW-Series Pond Pumps

Add
TidalWave2 TW-Series Pond Pumps

  0 of 0 people found the following review helpful:
 
AquascapePRO™ 7500 Pump August 15, 2011
Reviewer: Robert Drean from Parker, CO United States  
Your price was competitive,  Your communication excellent and the product arrived quickly.  Everything was A+.

Was this review helpful to you?

  0 of 0 people found the following review helpful:
 
AquascapePRO 7500 Pump July 12, 2011
Reviewer: Gary from Grapevine, TX United States  
I was a little unsure about ordering the pump online but it worked out well in the end. I would order again from Lochness.

Was this review helpful to you?


Browse for more products in the same category as this item:

Pond Pumps


Aquascape 9 Watt UV Bulb With Ballast $47.98
Aquascape Stacked Slate Fountain $119.98
Aquascape Barbed 90 Degree Elbow 3/4" $2.06
Pond Cleanout Pump Kit $347.99
Aquascape Threaded Union Fitting 1-1/4" $20.78
Grande BIOFALLS® Filter $934.99
Aquascape Pro 3000 GPH Pump $452.39
Aquascape Brass Mushroom Spitter $799.98
Aquascape Pro Black Silicone - 10.1 Oz $8.69